Loss Baseline & Measurement
Establishing what is actually being lost — reconciling gauging, temperature and movement records into a defensible monthly loss figure before anything is changed.
Evaporation is the quietest line item in a gasoline terminal's accounts: product leaves the tanks as vapor, revenue leaves with it, and emissions rise in parallel. Many operators book 0.5–1% monthly losses as a cost of doing business. It usually isn't — it's a list of specific, findable, fixable loss paths.
At Cogico's Jieh terminal, this practice diagnosed those paths — seal condition, breathing-valve setpoints, fitting integrity — and executed targeted calibration and modifications. Monthly gasoline losses fell from 0.8% to 0.05%, a 94% reduction, deliberately validated during the hottest months of the year so the result would hold in the worst case, not just the average one.
Establishing what is actually being lost — reconciling gauging, temperature and movement records into a defensible monthly loss figure before anything is changed.
Physical inspection of tank bodies and accessories — seals, roof fittings, vents and breathing devices — separating tank-fabric leaks from breathing-loss mechanisms instead of guessing.
Targeted fixes per loss path: seal and fitting upgrades, pressure-vacuum valve calibration and setpoint optimization, and operational changes — engineered, executed and supervised.
Inert-gas blanketing and pressure-control design where product protection demands it — as engineered for FAP's hygroscopic polyol storage in Ghana — plus vapor-handling option studies for gasoline service.
Performance confirmation under peak ambient temperatures — the operating condition that breaks half-measures — so the loss reduction is real in August, not just in the report.
Emissions-reduction documentation for regulators and a recovered-product accounting the finance team can verify against stock records.
Engagements run project-based (defined scope and deliverables), as a standing technical advisory retainer, or start small with a fixed-scope audit — see engagement models.
A handful of mechanisms: standing (breathing) losses through vents and poorly set pressure-vacuum valves, working losses during filling and emptying, seal and fitting leakage on the tank itself, and occasionally measurement error masquerading as loss. An inspection-led audit separates them — because each has a different fix.
It depends entirely on the starting condition — which is why the audit begins with a measured baseline. As a reference point: the Cogico programme took a terminal accepting 0.8% monthly losses down to 0.05%, a 94% reduction that held under peak-summer temperatures.
No. The programme is inspection-led and tank-by-tank: diagnosis, calibration and modifications are sequenced around normal receipt and dispatch operations.
Both, by construction: every kilogram of vapor that stays in the tank is product you sell instead of emissions you report. The same programme produces the commercial recovery and the environmental-compliance improvement.
A short description of your facility and challenge is enough to start. You'll get a discovery call invitation and an initial qualification questionnaire — available worldwide.