Fire Scenario & Demand Definition
Credible-scenario analysis — full-surface tank fire, rim-seal fire, bund fire — converted into foam and cooling-water demand calculations the system is actually sized against.
Tank farm fire protection is the one system an operator buys hoping never to use — and the one where a design shortfall is unaffordable. Scenario definition, foam application rates, water demand and pumping reliability have to be engineered against the worst credible fire, not the most convenient one.
This practice designs firefighting systems beyond NFPA and API minimums where the risk justifies it: the IPT Terminal system combines dual foam agents (AFFF and fluoroprotein) with fixed protection and long-range monitors, delivered through testing, commissioning, standing instructions and operator training. At SAMIR, the refinery's firefighting infrastructure was upgraded to current international standards across a 27-tank facility — coordinated with live operations throughout.
Credible-scenario analysis — full-surface tank fire, rim-seal fire, bund fire — converted into foam and cooling-water demand calculations the system is actually sized against.
Foam concentrate selection, proportioning, foam chambers and pourers, and long-range monitors for bunded areas — including dual-agent (AFFF / fluoroprotein) architectures for mixed open and closed hazards.
Ring mains, hydrant and monitor coverage, tank cooling arrangements and network hydraulics — engineered so the demand case is met at the furthest, highest nozzle.
Fire pump station design to NFPA 20 plus the discipline most designs miss: generator sizing for firefighting duty and large-motor starting, specification, earthing and protection.
Detection philosophy, alarm and control interfaces, and coordination with drainage so firewater and fuel are managed — not just discharged — during an event.
Upgrading live facilities without leaving them unprotected mid-works; performance testing, commissioning, standing instructions and hands-on operator training at handover.
Engagements run project-based (defined scope and deliverables), as a standing technical advisory retainer, or start small with a fixed-scope audit — see engagement models.
NFPA 30 for the flammable-liquids facility itself, NFPA 11 for foam systems, NFPA 20 for fire pumps, with API RP 2021 informing tank-fire response — plus whatever the local civil-defense authority requires. Where the risk justifies it, we design beyond the code minimum, not to it.
Yes, with sequencing discipline: the SAMIR firefighting upgrade ran across a live refinery tank farm for three years, coordinated with operations and HSE so protection was maintained throughout the works.
By hazard: product class, tank type, open versus closed areas and environmental constraints. The IPT design used a dual-agent architecture — AFFF and fluoroprotein — matched to different areas of the same terminal, rather than forcing one agent to cover everything.
Yes — including the part that is often missed: emergency generator sizing for firefighting duty with large-motor starting loads, plus specification, protection and earthing. Power generation engineering is a core discipline of the practice.
A short description of your facility and challenge is enough to start. You'll get a discovery call invitation and an initial qualification questionnaire — available worldwide.