Skip to main content
Back to all projects
Chemical StorageGhana

Moisture Control System — FAP Polyol Oil Storage

Dry-air / nitrogen blanketing, tank safety accessories and automated pressure control to keep hygroscopic polyol product dry across all loading, unloading and thermal scenarios.

Case study published 18 May 2026 · Last reviewed 20 May 2026

Location
Tema, Ghana
Duration
4 months
End Client
FAP
Role

Detailed Design · Material Procurement Assistance

Case study PDFÉtude de cas (FR)

Zero
Product contamination
Auto
Pressure control
4 mo
Concept to procurement
Project Background

The context that shaped the engineering.

FAP operates a polyol storage facility at Tema, Ghana's primary industrial port and petrochemical hub. Polyols are highly hygroscopic chemical intermediates: exposure to atmospheric moisture during storage triggers hydrolysis reactions that degrade product quality, generate contaminants and shorten usable shelf life. For a storage operator handling polyols at industrial scale, controlling moisture ingress is therefore not a routine maintenance issue but a core product-protection requirement. The project objective was to design and procure a complete moisture control system for FAP's polyol storage tanks — covering the inert atmosphere generation and distribution circuit, the associated tank safety accessories, and the pressure control equipment required to keep the tanks operating safely under all loading, unloading and ambient temperature conditions.
Scope of Services

What was delivered.

01

Detailed Design

Dry-air / nitrogen blanketing — inert gas supply, distribution piping, tank connections and pressure-vacuum control architecture.

02

Tank Safety Accessories

Pressure-vacuum relief, flame protection and emergency venting specified in line with applicable storage codes.

03

Pressure Control Equipment

Automated regulation of blanket gas supply and relief setpoints — stable internal pressure across breathing, transfer and thermal swings.

04

Material Procurement Assistance

Technical specifications, vendor qualification support and procurement of the complete moisture control package.

Design Solution

How the engineering came together.

Integrated multidisciplinary delivery

The system was engineered to maintain a continuous dry inert atmosphere above the stored polyol, isolating the product from ambient moisture under all operating modes. Blanket gas supply is regulated automatically against tank pressure: gas is admitted as tank pressure falls (during product outflow or temperature contraction) and excess pressure is relieved through dedicated safety devices (during product inflow or temperature expansion). The combination of automated pressure regulation and properly specified safety accessories was sized to handle the worst-case filling, emptying and thermal transient scenarios for the FAP tank fleet, while keeping operator intervention to routine inspection only.

Key Outcomes

The results the client took to operations.

Product Protection

Prevented hydrolytic contamination of stored polyol and extended usable shelf life by maintaining a dry inert atmosphere at all times.

Automated Pressure Control

Optimal storage conditions across loading, unloading and ambient temperature cycles with minimal operator intervention.

Safety Compliance

Integrated tank safety accessories ensure protection against both over-pressure and vacuum scenarios under all anticipated conditions.

Rapid Delivery

Full detailed design and material procurement assistance scope completed within a four-month programme — minimal facility downtime.

Disciplines Covered

Multidisciplinary by design.

ProcessMechanicalPipingInstrumentation & ControlStorage Tank EngineeringHazardous Product StorageSafety Engineering
Need this capability?

The services behind this project, explained in depth.

Your project

Have a similar engineering problem on your asset?

Send the brief — Eng. Naim replies personally with a discovery-call invitation and a short qualification questionnaire.